The best time to find a problem with steel is before it goes into your foundation. These checks take about half an hour and need nothing more than a tape, a scale and the delivery papers.
1. Read the markings on the bars
Genuine TMT bars have the brand, grade and size rolled into them at regular intervals. Look for the brand name, a grade such as 500D or 550D, and the diameter. Bars with no marking, or with markings that differ from your order, need an explanation.
2. Match the bundle tag and the mill test certificate
Each bundle carries a tag with the brand, size and a heat number. The mill test certificate lists the same heat number. If they do not match, you cannot tell which test results belong to your steel. Here is how to read the certificate.
3. Look at the weighbridge slip
A good supplier weighs the truck loaded and gives you the slip. Compare the net weight with your bill. Ask for the slip even for small loads.
4. Weigh a few sample bars
Pick a few bars at random and weigh them on a scale. Compare with the theoretical weight below. The standard allows a small tolerance, so a bar slightly off the chart is normal. A whole load that is clearly under is not.
| Diameter | kg per metre | kg per 12 m bar |
|---|---|---|
| 8 mm | 0.395 | 4.7 |
| 10 mm | 0.617 | 7.4 |
| 12 mm | 0.889 | 10.7 |
| 16 mm | 1.580 | 19.0 |
| 20 mm | 2.469 | 29.6 |
| 25 mm | 3.858 | 46.3 |
| 32 mm | 6.321 | 75.9 |
You can work out any length with our steel weight calculator.
5. Look at the surface and shape
- Ribs should be even and continuous along the bar.
- Light surface rust is common and usually fine. Deep pitting or thick flakes that come off by hand are not.
- Bars should be straight, with no cracks and no kinks from rough handling.
If something looks wrong
Write the problem on the delivery challan before you sign, take clear photos of the markings, tags and slip, and call the supplier the same day. Do not use the steel until your engineer has looked at it.